Scanning image
Technical Parameters:
General Specification |
||
Tunnel Size | 1400mm(width) ×1000mm(height) | |
Conveyor Speed | 0.6-0.9m/s | |
Conveyor Height | Customized | |
Wire Resolution | 40AWG(0.0787mm of wire) | |
Spatial Resolution | horizontal Ф1.0mm vertical Ф1.0mm | |
Steel Penetration | 38mm | |
Monitor | 17-inch color monitor with resolution:1280×1024 | |
X-ray Generator | ||
Anode Voltage | 200w,160kv | |
Cooling/Run Cycle | sealed oil cooling/ 100% | |
Image Processing System | ||
Image Enhancement Features | color/black & white image ,organic and inorganic elimination ,alterable absorption, super-enhancement, negative mode, high/low energy penetrability, pseudo color etc | |
Image Resolution | organics: orangeinorganic: bluemixture and light metal: green | |
Radiation Safety | ||
Radiation Leakage | less than 1.5μGy /h ( 5cm away from shell)comply with all domestic and international health and radiation safety standards | |
Film Safety | in accordance with ASA/ISO1600 film safe standard | |
Scanning system | ||
AI camera/ Industry camera, Top/side/Multi scanning | ||
Indicator Functions | ||
Three-colors indicators:Green: on: working ; blink: pauseYellow: on: trouble
Red: on: emergency on /pause Blue: on: direct mode |
||
Installation Data | ||
External Dimension | 1125mm(length) ×2226mm(width) ×1660mm(height) | |
Packing Size | 1300mm(length) ×2500mm(width) ×1900mm(height) | |
Weight | 900Kg | |
Operation Voltage | AC220V(-15%~+10%) 50±3Hz | |
Power Consumption | 1.5kVA | |
Operation Temperature | 0℃±3℃~+40℃±2℃ | |
Storage Temperature | -40℃±3℃~+60℃±2℃ | |
Relative Humidity | 30%~95%(non-condensing) |